Products Specifications:
Warranty Information & Policy | 2 Years Compressor Warranty |
1 Year Spare Parts Warranty | |
1 Year Service Warranty | |
Model | Indoor (50Hz) - CS-S18PKH |
Outdoor (50Hz) - (CU-S18PKH) | |
Cooling Capacity | Btu/h - 18,000 (3,750-20,500) |
kW - 5.27 (1.10-6.00) | |
EER | Btu/hW - 12.2 |
Phase | ø - 1 |
Electrical Data | Voltage (V) - 230 |
Running Current (A) - 6.8 | |
Power Input (W) - 1,470 (290-1,700) | |
Moisture Removal | L/h - 2.9 |
Pt/h - 6.1 | |
Air Circulation (Indoor/Hi) | m³/min. - 17.7 |
ft³/min. - 625 | |
Dimensions | Height (mm) - 290 (619) |
Height (inch) - 11-7/16 (24-3/8) | |
Width (mm) - 1,070 (824) | |
Width (inch) - 42-5/32 (32-15/32) | |
Depth (mm) - 240 (299) | |
Depth (inch) - 9-15/32 (11-25/32) | |
Net Weight | kg - 12 (32) |
lb - 26 (71) | |
Refrigerant Pipe Diameter | Liquid Side (mm) - ø 6.35 |
Liquid Side (inch) - ¼ | |
Gas Side (mm) - ø 12.70 | |
Gas Side (inch) - ½ | |
Pipe Extension | Chargeless Pipe Length (m) - 10 |
Maximum Pipe Length (m) - 20 | |
Maximum Elevation Length (m) - 15 | |
Additional Refrigerant Gas* (g/m) - 15 | |
Power Supply | Indoor |
Cleaner Air | nanoe-G - Yes |
Anti-Bacterial Filter - No | |
Odour-Removing Function - Yes | |
Removable, Washable Panel - Yes | |
Catching Air Purifying Filter - No | |
Solar Refreshing Deodorizing Filter - No | |
Comfort | ECONAVI - Yes |
Temperature Wave - Yes | |
AUTOCOMFORT - Yes | |
Inverter Control - Yes | |
Mild Dry Cooling - Yes | |
Quiet Mode - Yes | |
Powerful Mode - Yes | |
Soft Dry Operation Mode - Yes | |
Personal Airflow Creation - Yes | |
Airflow Direction Control (Up Down) - No | |
Manual Horizontal Airflow Direction Control - No | |
Manual Airflow Direction Control (Left Right) - No | |
Sleep Mode Auto-Control - No | |
Automatic Operation Mode (Cooling) - Yes | |
Convenience | 24-Hour Dual ON OFF Real Setting Timer - Yes |
24-Hour ON OFF Real Setting Timer - No | |
12-Hour ON OFF Setting Timer - No | |
LCD Wireless Remote Control - Yes | |
Wired Remote Control - No | |
Reliability | Auto Restart - No |
Random Auto Restart (32 Restart Patterns) - Yes | |
Blue Fin Condenser - Yes | |
Long Piping (Numbers indicate the maximum pipe length) - 15m | |
Top-Panel Maintenance Access - Yes | |
Self-Diagnostic Function - Yes | |
NOTE | Caution For CS-S10/S13/S15/S18/S24PKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. * When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit. |