UK Plug 220V 5 in 1 40KHZ Ultrasonic Cavitation Radio Frequency RF Body Slimming Beauty Machine Rejuvenation -

(0 Reviews)
Brand
No Brand

Inhouse product


Price
৳59,640.90
Quantity
(0 available)
Total Price
Refund
Not Applicable
Share

Reviews & Ratings

0 out of 5.0
(0 Reviews)
There have been no reviews for this product yet.

UK Plug 220V 5 in 1 40KHZ Ultrasonic Cavitation Radio Frequency RF Body Slimming Beauty Machine Rejuvenation

Description:

Type:RF Beauty Machine

Power supply Input:220V

Plug:UK Plug

Power:130W

?

40K Cavitation?head:

Power supply output:150V

Frequency:40KHz

Power:25W

?

Vacuum+Bipolar RF head:

Power supply output:66V

Frequency:450K

Power:95W

?

BIO head:

Power supply output:24V

Frequency:1.5K

Power:1W

?

Tripolar RF head:

Power supply output:66V

Frequency:450K

Power:35W

?

Face RF head:

Power supply output:66V

Frequency:450K

Power:35W

Package Size:approx.31cmX29cmX42cm


Working principal:

With collective strong sound wave head, strong sound wave of 40000HZ may be

emitted to vibrate fat cells at top speed and produce numerous vacuum air pockets

inside and outside the fat cells, robustly impact fat cells to generate introverted blast

and disintegrate triglyceride into glycerol and free aliphatic?acid. Then RF waves at

frequency of 1M HZ is used for exhausting the integrated glycerol and free aliphatic?acid

through hepatoenteral circulation. Finally, vacuum RF and energy electrode are used

for positioning and tightening fat. In physics, it is known as "Cavitations". Micros-pore?

introverted blast inside and outside cell may lead to enhanced molecular motion and

a higher energy level and this will finally cause fat cell rupture and thereby achieve the

effects of body building and losing weight.

?

Function:

1.40Khz Ultrasonic handle(Strong sound wave explosion fat head)

With collective strong sound wave head, strong sound wave of 40000HZ may be emitted to human body for impacting fat cells fiercely and Causing friction motion between fat cells. This may cause effective consumption of calories and moisture in fat cells and reduce the size of fat cells. What's more, sound wave vibration may cause fierce impact of fat cells to make them be exploded instantaneously, reduce the amount of fat cells and thereby achieve the effects of removing fat

?

2.Vacuum Bipolar RF handle(For body and face re-shaping and weight loss)

Vacuum + RF fat-explosion machine can promote tissue metabolism, repel the cellulite, which make fat granule in different depths and shocking make energy, and the deepest receptor can get granule in 3CM thick of skin, and rapid expansion and the rapid

heating of the cell wall that exceed the elastic limits and arises cells broken, so that the combustion of aliphatic?acid at the same broken out of a pot, not only the burning consumption of aliphatic?acid but also more directly emptying so rapidly reduce the size of granule.

?

3.Tripolar RF

Stick to enhance rejuvenation: use of positive and negative micro-current activation energy release skin cells, so that paid synthesis of fibro-blasts collagen, elastic skin revert to the compact, the skin causing the eliminate wrinkles, prevent skin aging, restoring skin elasticity, facial improvement.

?

4.Body RF handle

Being integrated with the most advanced RF technology and radio frequency, the instrument may directly reach the deep-seated fat body and have the excellence of targeted positioning RF. In the fast-active state, fat cell tissue may generate friction heat, increase local temperature and remove excess fat and toxin from the body through sweat gland,enter hepatic circulation and lymph and ultimately achieve the effect of dissolving fat.With controlled depth technology, inlaid particles of different sizes may rub skin along its pattern, adjust suction strength by means of vacuum draw and rub with negative pressure strong force to directly explode thick fat. Thus, the effects are very obvious: Enhance blood circulation, accelerate the decomposition of fat, take away wastes, enhance the effect reproving cellulite, effectively improve the state of areola tissue, remove stubborn fat and improve the sufficient absorption condition of diet products.

?

5.Face RF head:(Facial wrinkle elimination, tightening and lifting)

A capacitive coupling electrode is used for transmitting radio-wave energy and generating an electric field for entering into subcutaneous tissue through the skin surface. In the high-frequency of 450 kHz, this electric field changes its polarity for 450,000 times per second. To reply to the rapid change in electrode, directions of electrical particles

the skin are also changed. By this , natural electric resistance in the subcutaneous tissue moves and generates heat energy. As the papillary dermis collagen may immediately shrink when the temperature is within the range from 60 to 70 Celsius degree, after wrinkle treatment, client may immediately sense the skin tightening effects as it is being lifted and firmed. When collagen is produced continuously, thickness and density of the skin papillary dermis may be increased to remove wrinkles, eliminate scars, restore skin elasticity and gloss and make it be blonde and smooth. While collagen is increased, fresh skin is generated in the position of operation and wrinkles are removed by large amount of cells. In addition, when cortex without elasticity or that with thick horny layer in the area with wrinkles is separated, surrounding skin will also be renewed.

?

Attention:

1. Pregnant women or women during in menses.

2. Epileptic.

3. Patients with malignancy.

4. Patient whose wound after operation has not healed up.

5. Acute inflammation or epidermic?patients.

6. Whom with heart diseases or with heart pacemaker.

7. Who with kidney (gall-stone) disease.

8. Who was embedded metal object or silica gel.

9. Who in menses, birth control period, emiction incontinence period, or accepting

the belly operation.

10. Whose body always takes much inner hot.

11. Who has the genetic hypersensitivity.

?

Tips:

1. Be sure to use the special ultrasonic gel.

2. Avoid knocking the us head.

3. For avoiding burning the head, during operation, please prepare enough

ultrasonic gel.

4. Do not stay in one place, avoid treating on the bone.

5. Do not use disinfectant product to disinfect the us head. We suggest the wet

cotton or dry towel enough.

6. Check the machine power cord if it is connected well.

7. If the machine will not use for a long , please switch off it, and power off.

8. Please take off all metal decoration from the operator and patient’s body.

9. If continuous using 1 hour, please pause the machine about 10 minutes, then

using again.

10.During the operation, be sure not to accept other treatment.

?

Notice:

1.The color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.

2.Please allow slight deviation for the measurement data.

3.Please allow 1-3cm error.

?

If?you?have?any?questions,?please?contact?us.

Wish?you?have?a?happy?shopping?!





















Support
All Categories
Flash Sale
Todays Deal